Maximum Use Length of Different Gauge Conductors

Driven by 12VDC x 5 Amp or 24VDC x 4 Amp Power Sources 5% & 10% Line Loss (LL)

Paige P/NDescriptionVoltageGaugeLL;LengthLLLength
98P183L&MRip Strip Plenum12VDC185%120 ft.10%19 ft.


24VDC

24 ft.
46 ft.
98P1814L&MRip Strip Plenum w/Ground12VDC185%10 ft.10%19 ft.


24VDC

24 ft.
46 ft.
984184&MRGB12VDC185%10 ft.10%19 ft.


24VDC

24 ft.
46 ft.
984182C&MPLTC / CM12VDC185%10 ft.10%19 ft.


24VDC

24 ft.
46 ft.
98P143L&MRip Strip Plenum12VDC145%25 ft.10%47 ft.


24VDC

58 ft.
117 ft.
984122C&MPLTC / CM12VDC125%40 ft.10%75 ft.


24VDC

150 ft.
295 ft.

THE ABOVE ARE APPROXIMATE VALUES. EACH "LED" MANUFACTURER HAS THEIR OWN ACCEPTABLE LINE LOSS (LL) VALUES. USER SHOULD CHECK WITH THE "LED" MANUFACTURER TO VERIFY THEIR ACCEPTABLE LIMITATION.